Automatic Safety Valve Setting Machine
Automatic Safety Valve Setting Machine
For water, air and water-heater safety valves, to support safety-valve setting and production inspection with a focus on opening pressure and internal or external relief pressure for water-heater valves. Circuits and fixtures are selected for the sample and required tests.
| Technical Specifications | |
|---|---|
| Test Specification | 1/2", 3/4", etc. |
| Configuration | High-precision sensors, servo adjustment unit, booster unit, pressure stabilizing unit, pressure reducing unit, PLC control system, etc. |
| Reference Standards | EN 1489, GB/T 20910 |
Product Overview
Application and test scope
Automatic Safety Valve Setting Machine is intended for water, air and water-heater safety valves. It is used to support safety-valve setting and production inspection with a focus on opening pressure and internal or external relief pressure for water-heater valves. The test arrangement is selected around the sample construction, service conditions and required evaluation method.
Tests and configuration
- Confirmation of the medium and opening-pressure measurement method
- Pressure verification after adjustment of the setting mechanism
- Separate records for internal and external relief tests on water-heater valves
Typical test workflow
Connect the fixture appropriate to the valve design, apply the agreed pressure sequence and record opening behaviour. Where setting is required, adjust and retest, keeping valve-specific records and acceptance criteria.
Selection information
For a suitable proposal, provide valve type, gas or liquid medium, target opening pressure, adjustment mechanism, connections and acceptance method. Product drawings or a sample help define connections, locating tooling and test circuits.
Measurement ranges, accuracy, automation, data interfaces and acceptance criteria are defined by the selected configuration and agreed technical proposal.
Existing equipment information

Equipment Name: Safety valve automatic setting machine
Application: Production testing
Products Tested: Water safety valves, gas safety valves and water-heater safety valves
Purpose: Automatic setting of safety valve opening pressure; testing of internal and external discharge pressure of water-heater safety valves
Test Specification: 1/2″, 3/4″, etc.
Configuration: High-precision sensors, servo adjustment unit, booster unit, pressure stabilizing unit, pressure reducing unit, PLC control system, etc.
Reference Standards: EN 1489, GB/T 20910
Interested in this equipment?
Tell us your testing needs — we will tailor a solution for you