Special and Safety Valve Tests: Fire, Cryogenic, Emissions, Type Test

Special tests differ from routine pressure testing not because the bench is more expensive, but because the sample’s state is irreversible. A valve that has been through a fire cannot then be cryogenically tested; a graphite packing measured for fugitive emissions changes its friction the moment it is disturbed. Sequence, sample count and re-test points matter more than bench specifications.

This cluster covers fire, cryogenic, fugitive emissions, type testing, safety valves, liquid cooling and aggressive media — all of which come down to the same three questions: what to run first, how many samples, and what counts as done.

1. Sequencing the special tests

Test Basis Sample altered? Recommended order
Fugitive emissions ISO 15848-1, API 624/641 Yes (packing bedding-in) First, before any strip-down
Cryogenic ISO 28921-2, BS 6364, GB/T 24925 Yes (seat condition after deep cold) Not after fire
Fire ISO 10497, API 607 Yes, irreversibly Last; judged on leakage only
Type test TSG D7002-2023 Not necessarily All sub-items allocated across one sample set

Get the order wrong and the earlier data is wasted. The most common waste is running fire first and emissions second — after the burn the packing has changed and the emission figure means nothing.

2. Find the article by question

Fire and cryogenic

Fugitive emissions and micro-leakage

Type testing and safety valves

Liquid cooling and aggressive media

3. Three misjudgements

Running every special test on one sample. Fire, cryogenic and emissions conflict: emissions needs a bedded-in packing, cryogenic needs a fresh seat, fire destroys the packing. That is why type-test sampling rules specify a sample count. Short of samples, the data has to be cherry-picked.

Reading “no leak” as a pass. The fire criterion is leakage during the burn and after cool-down, not appearance; the cryogenic criterion includes operating torque at temperature, not only tightness. Judging on leakage alone drops half the criteria.

Writing coverage wider than it is. TSG D7002-2023 coverage has hard boundaries: pressure, size, temperature, construction. Using a DN50 result to cover DN300, or a soft-seat result to cover metal-seat, gets rejected on review. Write the coverage table structure by structure, class by class.

4. Configuring the bench

Special tests rarely run on one machine. The practical split is a general bench for routine pressure and tightness, and dedicated tooling for the specials. Fire needs a burn pit and thermocouples, cryogenic needs a cold source and insulated spool, emissions needs a fixed-volume sampling enclosure — in all three, the tooling matters more than the host machine.